Developer docs
API playgroundTry for free, no card

Search company profiles

Circle Cardiovascular Imaging

Full company profile

uuid0000qcq

Namestring
Circle Cardiovascular Imaging
Legal namestring
Circle Cardiovascular Imaging Inc.
Websiteurl
circlecvi.com
Company typeenum
Private
Founded yearint
2007
Descriptiontext

Circle Cardiovascular Imaging (Circle CVI), founded in 2007 in Calgary, Canada, develops and markets cvi42, a vendor-agnostic post-processing software platform for cardiovascular and neurovascular imaging analysis. The platform is deployed across 1,700+ hospital sites in 90+ countries, including 70% of the world's top 50 hospitals (per Newsweek 2023 rankings), and processes 50,000+ cardiac scans daily. cvi42 spans cardiac MR, cardiac CT, vascular CT, interventional planning (TAVR/TMVR/WATCHMAN), electrophysiology, and acute stroke imaging (StrokeSENS), integrating with all major scanner vendors (GE, Siemens, Philips, Canon), PACS systems via DICOM, and reporting systems via HL7. The company is privately held under Thoma Bravo ownership following a 2022 growth investment, with 101-250 employees and wholly-owned subsidiaries in the UK, Netherlands, and USA.

The cvi42 platform is built around AI-powered image analysis using convolutional neural networks trained on multi-vendor, multi-center datasets including UK Biobank. AI capabilities include automated cardiac contouring and segmentation, zero-click calcium scoring, AI-enabled coronary plaque quantification (FDA-cleared cvi42 | Plaque), 4D Flow analysis, automated ASPECTS scoring, and LVO detection for stroke triage. AI models are frozen, encrypted, and run on-premise, ensuring patient data never leaves the institution. The company holds multiple FDA 510(k) clearances, EU MDR CE mark, ISO 13485:2016, MDSAP certification, and regulatory approvals in 20+ jurisdictions.

Circle CVI generates revenue through a hybrid model combining annual subscription licensing (including the cvi42 | Elevate flexible subscription and module-specific add-ons), usage-based per-case fees for AI-enabled plaque analysis (now reimbursable under new CPT code 75577 at ~$950-$1,012 per case), enterprise site licenses, and professional services for implementation and HL7 integration. Distribution combines direct enterprise sales, OEM integration with GE Healthcare and Siemens Healthineers, a 600+ OEM distributor network, and self-serve trial downloads. The company serves hospital systems, academic medical centers, cardiology and radiology departments, structural heart and EP programs, and rural/community hospitals globally.

Short descriptiontext

Circle Cardiovascular Imaging develops cvi42, a vendor-agnostic AI-powered cardiovascular and neurovascular imaging post-processing platform. Deployed across 1,700+ hospital sites in 90+ countries, serving cardiology, radiology, and stroke programs globally.

Operating statusenum
Operating
Ownership categoryenum
Headcount rangeband
101–250
akta.pro rankint
HeadquartersCalgary, Canada
HQ citystring
Calgary
HQ countrystring
Canada
HQ regionstring
North America
Markets served

Serves global market

Offices2 records

Each record includes

City, Country, Type, Description, Source

Keyword5 values
cardiovascular imaging software, cardiac MR analysis, coronary plaque analysis, medical imaging AI, post-processing software
Industry2 codes
1Imaging & Cardiac Safety Core Labs (ECOG/EEG/ECG)
CodeHLAGAAAJPrimaryYes
2Decentralized/Hybrid Trial Enablement (DCT) Platforms
CodeHLACAOALPrimaryNo
NAICS code1 code
  • Software Publishers513210
SIC code1 code
  • Surgical & Medical Instruments & Apparatus3841
Product category
Cardiovascular Imaging Software
Social media profiles1 record
GTM motion4 records

Each record includes

Type, Description, Source

Revenue model3 records
1Software Licenses (Subscription)
TypeSubscription Recurring
Description

Annual subscription model for cvi42 platform access. Flexible subscription model (cvi42 | Elevate) provides scalable access to CMR and CCT functionalities with unlimited usage. Sites can subscribe to specific modules based on their needs.

circlecvi.com
2Per-Use/Transaction Revenue
TypeUsage Based
Description

Usage-based pricing for plaque analysis processing. Sites pay for what they process at a per-case rate, particularly for cvi42 | Plaque workflow. Reimbursable under CPT code 75577 for AI-enabled coronary plaque analysis.

circlecvi.com
3Professional Services
TypeProfessional Services
Description

Implementation services, training, and technical support services. HL7 integration services available as additional purchase. Initial setup and configuration support for enterprise deployments.

globenewswire.com
Marketing channels6 records

Each record includes

Title, Type, Stage, Description, Source

Distribution channels5 records

Each record includes

Title, Type, Scope, Target buyer, Description, Source

Cost components5 values
Technology or R&D, Personnel, Marketing or Sales, Operations, Others
Pricing details4 tiers
1cvi42 | Elevate Subscription Model
ModelSubscriptionBilling cadenceAnnual
Notes

Scalable subscription model providing unlimited access to CMR and CCT functionalities. Enables teams to work from anywhere with full platform access. Annual billing with flexible scaling options.

circlecvi.com
2Per-Use Pricing for Plaque Analysis
ModelUsage-basedBilling cadencePay-as-you-go
Notes

Pay-for-what-you-process model for cvi42 | Plaque at a fraction of outsourcing costs. Provides streamlined workflow with increased throughput compared to external reading services.

circlecvi.com
3Enterprise Site Licenses
ModelSubscriptionBilling cadenceAnnual
Notes

Site-based licensing for hospital outpatient departments and imaging centers. Includes all cvi42 modules with multi-user concurrent access through Client/Server deployment.

circlecvi.com
4Module-Specific Add-ons
ModelSubscriptionBilling cadenceAnnual
Notes

Additional licenses required for specific modules including cvi42 | Strain, cvi42 | Report (HL7 integration), cvi42 | 4D Flow, and cvi42 | Quantitative Perfusion (research use only).

globenewswire.com
GTM typeB2B
B2B
Offering typeSoftware
Software
Brand1 of 5 records shown
1cvi42
Description

The company's flagship cardiovascular imaging software platform providing quantitative and qualitative assessment of cardiac MR, cardiac CT, vascular CT, and neuro CT.

circlecvi.com
+4 more records
Core offering1 text field

Circle Cardiovascular Imaging develops and markets cvi42, a vendor-agnostic AI-powered post-processing platform for cardiovascular and neurovascular imaging. The software provides automated quantification and analysis of cardiac MR, cardiac CT, vascular CT, structural heart interventional planning, electrophysiology, and acute stroke imaging, deployed at hospital systems and academic medical centers. It sells primarily through annual subscriptions, usage-based pricing for plaque analysis, and OEM integrations with GE Healthcare and Siemens Healthineers.

Differentiator
Functional benefit
Problem solved
Quantifiable outcome1 of 6 values shown
  • Customer Satisfaction Score (CSAT) of 4.9 out of 5 with 98% satisfaction rate
+5 more records
Product overview1 text field

Circle Cardiovascular Imaging offers cvi42, a unified, vendor-agnostic cardiovascular imaging platform. The platform is built around a core cvi42 software that supports all operating systems (Mac and Windows) and all scanner vendors, deployed as standalone workstation or Client/Server. The platform integrates modules for Cardiac MR (function, flow, tissue characterization, strain, 4D Flow, perfusion), Cardiac CT (CORE CT with coronaries/calcium/function/strain, Plaque analysis, PCAT), Vascular CT (via Astute Imaging), Interventional Planning (TruPlan, aortic/mitral valve), Electrophysiology (ADAS 3D), and Neuro CT (StrokeSENS for LVO and ASPECTS). The cvi42 platform serves over 1,700 hospitals in more than 90 countries and processes scans daily.

Product and service6 records
1cvi42
CategoryCardiovascular Imaging Platform
Description

Flagship vendor-agnostic cardiovascular imaging platform providing quantitative and qualitative assessment across cardiac MR, cardiac CT, vascular CT, and neuro CT. Supports all major scanner vendors and runs on Mac and Windows, deployed as a standalone workstation or Client/Server, and integrates with PACS, PowerScribe, and hospital reporting systems via HL7 and DICOM.

2cvi42 | Plaque
CategoryCardiac CT Imaging Module
Description

FDA-cleared AI-enabled coronary plaque analysis module providing on-premise quantification of atherosclerotic burden from CCTA studies, including automated coronary lumen and wall segmentation, per-lesion and per-vessel analysis of calcified, non-calcified, and low-attenuation plaque, and remodeling index assessment for high-risk plaque identification.

3cvi42 | Vascular CT
CategoryVascular CT Imaging Module
Description

AI-enabled vascular CT analysis module for aortic (AAA, TAA), carotid, and peripheral artery assessment, powered by Astute Imaging technology. Features AI-powered segmentation of lumen, thrombus, calcium, and plaque, automated centerline extraction, virtual graft simulation with FEM analysis, and bilateral comparison for disease progression tracking. Licensed by Astute Imaging and distributed by Circle CVI.

4StrokeSENS
CategoryNeuro CT Imaging Module
Description

AI-based stroke imaging software for front-line physicians. Includes StrokeSENS LVO for flagging and prioritizing suspected Large Vessel Occlusion on CT/CTA, and StrokeSENS ASPECTS for automatic Alberta Stroke Program Early CT Score scoring on non-contrast CT. FDA-cleared and CE-marked, and available via GE AW workstation/server, Siemens syngo.via, and Aidoc's aiOS platform.

5cvi42 | Interventional Planning (TruPlan)
CategoryStructural Heart Intervention Planning Module
Description

Pre-procedural planning module for structural heart interventions including WATCHMAN TruPlan for left atrial appendage closure (LAA assessment, fluoro/TEE/ICE simulation, follow-up PDL measurement), Aortic Valve planning (annulus measurements, cusp detection, virtual device visualization, femoral access planning), and Mitral Valve planning (annulus contouring, LVOT assessment, neo-LVOT, apical access planning, trans-septal measurements).

6cvi42 | Electrophysiology (ADAS 3D)
CategoryElectrophysiology Planning Module
Description

Pre-procedural imaging tools for electrophysiologists, using ADAS 3D (licensed and manufactured by Adas3D Medical and distributed by Circle CVI). ADAS 3D LV visualizes and quantifies LV fibrosis (MR) and anatomical structures (CT) with myocardial layer display, while ADAS 3D LA visualizes fibrosis distribution in 3D from late enhancement MR with adjacent structure display.

Scale indicator10 records

Each record includes

Type, Value, Description, Source

Partnership4 partners
Strategic tierCoreTypeStrategic or Co-development PartnerAnnounced on2026-03-18
Description

Strategic collaboration integrating Astute Imaging's AI-driven vascular analysis technology (aorta, carotid, peripheral arteries) into cvi42 platform. Enables comprehensive cardiovascular workflows including cardiac, vascular, and structural heart analysis in unified platform.

Strategic tierStrategicTypeStrategic or Co-development PartnerAnnounced on2025-12-18
Description

Strategic partnership integrating Circle's automated ASPECTS capabilities into Aidoc's aiOS enterprise operating system for neurosciences AI. Enhances Aidoc's stroke diagnosis portfolio with Circle's MR perfusion and automated ASPECTS tools.

Strategic tierCoreTypeTechnology or Integration
Description

cvi42 integrated into GE AW workstation and AW Server. Native integration enables seamless cardiac imaging workflow for GE customers. StrokeSENS also integrated into GE FastStroke software package.

Strategic tierCoreTypeTechnology or Integration
Description

cvi42 available on Siemens Healthineers syngo.via workstation. Seamless integration enables cardiac imaging analysis within existing Siemens clinical workflow. StrokeSENS also available on Siemens platforms.

Recent move7 records

Each record includes

Date, Type, Title, Description, Source

Expansion highlight6 records

Each record includes

Type, Description

Peers10 records
TypeBroad incumbent
Description

GE HealthCare's AW Workstation and AW Server bundle Circle's cvi42 alongside GE's own AI imaging portfolio (including FastStroke). GE is both a critical OEM distribution channel and a potential competitor as it expands proprietary AI capabilities.

TypeDirect peer
Description

RapidAI offers AI-powered stroke and vascular imaging analysis, directly competing with StrokeSENS in LVO detection, ASPECTS scoring, and CT/MR perfusion quantification across hospital systems.

TypeDirect peer
Description

HeartFlow provides AI-driven coronary CT analysis (FFR-CT) for coronary artery disease assessment. It directly competes with cvi42 | Plaque in the CCTA post-processing market and targets the same cardiology departments.

TypeBroad incumbent
Description

Siemens Healthineers' syngo.via is both an OEM distribution partner for Circle (cvi42 is integrated into syngo.via) and a direct competitor offering its own AI-powered cardiovascular and CT post-processing tools within the same enterprise accounts.

TypeDirect peer
Description

Cleerly is an AI-native direct competitor to cvi42 | Plaque, focused exclusively on coronary plaque quantification and CAD risk stratification from CCTA. Both companies target the same CPT 75577 reimbursement-driven US opportunity.

TypeDirect peer
Description

Medis is a closely comparable niche cardiovascular imaging software vendor offering post-processing for cardiac MR, CT, and IVUS. It competes with Circle in academic medical centers and tertiary cardiac centers, particularly in Europe.

TypeDirect peer
Description

Viz.ai is the leading AI stroke detection and workflow platform, directly competing with Circle's StrokeSENS module for LVO detection and ASPECTS scoring in hospital neurology and stroke programs.

TypeDirect peer
Description

Aidoc is both a Circle partner (Circle's stroke AI is integrated into Aidoc's aiOS) and a broader AI imaging competitor across neurology, cardiology, and radiology workflows. Its enterprise AI operating system overlaps with Circle's hospital penetration strategy.

TypeDirect peer
Description

Elucid provides AI-based cardiovascular imaging analysis with a focus on plaque characterization and histology-validated quantification. It competes with cvi42 | Plaque in the coronary CT analysis category.

TypeBroad incumbent
Description

Philips offers IntelliSpace Portal and a dedicated Cardiovascular Workspace for advanced MR/CT post-processing. It is a broad incumbent imaging vendor that competes head-to-head with cvi42 in hospital cardiology and radiology departments globally.

Market position
Strengths5 records

Each record includes

Headline, Details, Source

Weaknesses5 records

Each record includes

Headline, Details, Source

Competitive moat6 records

Each record includes

Type, Details

Key risks6 records

Each record includes

Headline, Details, Source

Key highlights7 records

Each record includes

Headline, Details, Source

Customer concentration

Classification, Details

Named customers12 records

Each record includes

Name, Industry, Type, Use case, Source, UUID

Segment4 records

Each record includes

Title, Type, Primary, Description, Pain point addressed, Use case, Source

Ideal customer profile2 records

Each record includes

Profile, Firmographic size, Sales motion, Sales cycle length, Buying structure, Purchase trigger, Buyer persona, Geography, Industry vertical, Primary use case, Description, Pain points, Evidence proof points, Target buyer

Technology focused
Yes
API detail
Has APIbool
No

Docs URL, Description

Integration7 records

Each record includes

Title, Type, Description, Source

AI capability5 records

Each record includes

Type, Description, Source

AI maturity
App detail

Has app

Feature8 records

Each record includes

Title, Differentiator, Description, Source

Core technology
Revenue estimate
Valuation estimate
Number of profiles
Profiles7 records

Each record includes

Name, Designation, Designation category, Overview, Profile commentary, Source

Subsidiaries3 records

Each record includes

Name, Acquired on, Relationship type, Type, Business focus

Compliance5 records

Each record includes

Name, Class, Description

Funding overview

Funding stage, Last funding date, Total funding USD

Funding rounds5 records

Each record includes

Round, Amount USD, Date, Pre money valuation, Total investors, Investors, News

Investors9 records

Each record includes

Name, Type, Date of entry, Rounds participated, Website

Funding detail is available on the Subscription and Enterprise plan.Contact sales →

M&A1 record

Each record includes

Name, Acquisition type, Announced date, Completed date, Status, Website, News

Investment

Each record includes

Name, Round, Announced date, Lead investor, Website, News

M&A and investment is available on the Subscription and Enterprise plan.Contact sales →

Circle Cardiovascular Imaging

Cardiovascular Imaging Softwarecirclecvi.com

Circle Cardiovascular Imaging develops cvi42, a vendor-agnostic AI-powered cardiovascular and neurovascular imaging post-processing platform. Deployed across 1,700+ hospital sites in 90+ countries, serving cardiology, radiology, and stroke programs globally.

What Circle Cardiovascular Imaging does

Circle Cardiovascular Imaging (Circle CVI), founded in 2007 in Calgary, Canada, develops and markets cvi42, a vendor-agnostic post-processing software platform for cardiovascular and neurovascular imaging analysis. The platform is deployed across 1,700+ hospital sites in 90+ countries, including 70% of the world's top 50 hospitals (per Newsweek 2023 rankings), and processes 50,000+ cardiac scans daily. cvi42 spans cardiac MR, cardiac CT, vascular CT, interventional planning (TAVR/TMVR/WATCHMAN), electrophysiology, and acute stroke imaging (StrokeSENS), integrating with all major scanner vendors (GE, Siemens, Philips, Canon), PACS systems via DICOM, and reporting systems via HL7. The company is privately held under Thoma Bravo ownership following a 2022 growth investment, with 101-250 employees and wholly-owned subsidiaries in the UK, Netherlands, and USA.

The cvi42 platform is built around AI-powered image analysis using convolutional neural networks trained on multi-vendor, multi-center datasets including UK Biobank. AI capabilities include automated cardiac contouring and segmentation, zero-click calcium scoring, AI-enabled coronary plaque quantification (FDA-cleared cvi42 | Plaque), 4D Flow analysis, automated ASPECTS scoring, and LVO detection for stroke triage. AI models are frozen, encrypted, and run on-premise, ensuring patient data never leaves the institution. The company holds multiple FDA 510(k) clearances, EU MDR CE mark, ISO 13485:2016, MDSAP certification, and regulatory approvals in 20+ jurisdictions.

Circle CVI generates revenue through a hybrid model combining annual subscription licensing (including the cvi42 | Elevate flexible subscription and module-specific add-ons), usage-based per-case fees for AI-enabled plaque analysis (now reimbursable under new CPT code 75577 at ~$950-$1,012 per case), enterprise site licenses, and professional services for implementation and HL7 integration. Distribution combines direct enterprise sales, OEM integration with GE Healthcare and Siemens Healthineers, a 600+ OEM distributor network, and self-serve trial downloads. The company serves hospital systems, academic medical centers, cardiology and radiology departments, structural heart and EP programs, and rural/community hospitals globally.

Circle Cardiovascular Imaging firmographics

Firmographics
Name
Circle Cardiovascular Imaging
Legal name
Circle Cardiovascular Imaging Inc.
Website
https://circlecvi.com
Company type
Private
Founded year
2007
Operating status
Operating
Headcount range
101–250 employees
Short description
Circle Cardiovascular Imaging develops cvi42, a vendor-agnostic AI-powered cardiovascular and neurovascular imaging post-processing platform. Deployed across 1,700+ hospital sites in 90+ countries, serving cardiology, radiology, and stroke programs globally.
Ownership category
akta.pro rank

Circle Cardiovascular Imaging industry classification

Industry
Product category
Cardiovascular Imaging Software
NAICS
Software Publishers (513210)
SIC
Surgical & Medical Instruments & Apparatus (3841)
akta.pro primary industry
Imaging & Cardiac Safety Core Labs (ECOG/EEG/ECG) (HLAGAAAJ)
akta.pro secondary industry
Decentralized/Hybrid Trial Enablement (DCT) Platforms (HLACAOAL)

Keywords

  • Cardiovascular imaging software
  • Cardiac MR analysis
  • Coronary plaque analysis
  • Medical imaging AI
  • Post-processing software

Where Circle Cardiovascular Imaging is headquartered

Location

Headquarters

HQ city
Calgary
HQ country
Canada
HQ region
North America

Offices2 records

Markets served

Circle Cardiovascular Imaging business model

Business model
GTM type
B2B
Offering type
Software
Cost components
Technology or R&D, Personnel, Marketing or Sales, Operations, Others

Revenue model

  1. Software Licenses (Subscription): Annual subscription model for cvi42 platform access. Flexible subscription model (cvi42 | Elevate) provides scalable access to CMR and CCT functionalities with unlimited usage. Sites can subscribe to specific modules based on their needs.
  2. Per-Use/Transaction Revenue: Usage-based pricing for plaque analysis processing. Sites pay for what they process at a per-case rate, particularly for cvi42 | Plaque workflow. Reimbursable under CPT code 75577 for AI-enabled coronary plaque analysis.
  3. Professional Services: Implementation services, training, and technical support services. HL7 integration services available as additional purchase. Initial setup and configuration support for enterprise deployments.

Pricing tiers

ModelBillingPrice
SubscriptionAnnualcvi42 | Elevate Subscription Model
Usage-basedPay-as-you-goPer-Use Pricing for Plaque Analysis
SubscriptionAnnualEnterprise Site Licenses
SubscriptionAnnualModule-Specific Add-ons

Go-to-market motion4 records

Distribution channels5 records

Marketing channels6 records

Circle Cardiovascular Imaging product offering

Product offering

Core offering

Circle Cardiovascular Imaging develops and markets cvi42, a vendor-agnostic AI-powered post-processing platform for cardiovascular and neurovascular imaging. The software provides automated quantification and analysis of cardiac MR, cardiac CT, vascular CT, structural heart interventional planning, electrophysiology, and acute stroke imaging, deployed at hospital systems and academic medical centers. It sells primarily through annual subscriptions, usage-based pricing for plaque analysis, and OEM integrations with GE Healthcare and Siemens Healthineers.

Product overview

Circle Cardiovascular Imaging offers cvi42, a unified, vendor-agnostic cardiovascular imaging platform. The platform is built around a core cvi42 software that supports all operating systems (Mac and Windows) and all scanner vendors, deployed as standalone workstation or Client/Server. The platform integrates modules for Cardiac MR (function, flow, tissue characterization, strain, 4D Flow, perfusion), Cardiac CT (CORE CT with coronaries/calcium/function/strain, Plaque analysis, PCAT), Vascular CT (via Astute Imaging), Interventional Planning (TruPlan, aortic/mitral valve), Electrophysiology (ADAS 3D), and Neuro CT (StrokeSENS for LVO and ASPECTS). The cvi42 platform serves over 1,700 hospitals in more than 90 countries and processes scans daily.

Differentiator

Problem solved

Functional benefit

Brands

  • cvi42: The company's flagship cardiovascular imaging software platform providing quantitative and qualitative assessment of cardiac MR, cardiac CT, vascular CT, and neuro CT.
  • StrokeSENS
  • cvi42 | Plaque
  • TruPlan
  • cvi42 | Vascular CT

Products and services

  • cvi42 Flagship vendor-agnostic cardiovascular imaging platform providing quantitative and qualitative assessment across cardiac MR, cardiac CT, vascular CT, and neuro CT. Supports all major scanner vendors and runs on Mac and Windows, deployed as a standalone workstation or Client/Server, and integrates with PACS, PowerScribe, and hospital reporting systems via HL7 and DICOM.
  • cvi42 | Plaque FDA-cleared AI-enabled coronary plaque analysis module providing on-premise quantification of atherosclerotic burden from CCTA studies, including automated coronary lumen and wall segmentation, per-lesion and per-vessel analysis of calcified, non-calcified, and low-attenuation plaque, and remodeling index assessment for high-risk plaque identification.
  • cvi42 | Vascular CT AI-enabled vascular CT analysis module for aortic (AAA, TAA), carotid, and peripheral artery assessment, powered by Astute Imaging technology. Features AI-powered segmentation of lumen, thrombus, calcium, and plaque, automated centerline extraction, virtual graft simulation with FEM analysis, and bilateral comparison for disease progression tracking. Licensed by Astute Imaging and distributed by Circle CVI.
  • StrokeSENS AI-based stroke imaging software for front-line physicians. Includes StrokeSENS LVO for flagging and prioritizing suspected Large Vessel Occlusion on CT/CTA, and StrokeSENS ASPECTS for automatic Alberta Stroke Program Early CT Score scoring on non-contrast CT. FDA-cleared and CE-marked, and available via GE AW workstation/server, Siemens syngo.via, and Aidoc's aiOS platform.
  • cvi42 | Interventional Planning (TruPlan) Pre-procedural planning module for structural heart interventions including WATCHMAN TruPlan for left atrial appendage closure (LAA assessment, fluoro/TEE/ICE simulation, follow-up PDL measurement), Aortic Valve planning (annulus measurements, cusp detection, virtual device visualization, femoral access planning), and Mitral Valve planning (annulus contouring, LVOT assessment, neo-LVOT, apical access planning, trans-septal measurements).
  • cvi42 | Electrophysiology (ADAS 3D) Pre-procedural imaging tools for electrophysiologists, using ADAS 3D (licensed and manufactured by Adas3D Medical and distributed by Circle CVI). ADAS 3D LV visualizes and quantifies LV fibrosis (MR) and anatomical structures (CT) with myocardial layer display, while ADAS 3D LA visualizes fibrosis distribution in 3D from late enhancement MR with adjacent structure display.

Quantifiable outcome

  • Customer Satisfaction Score (CSAT) of 4.9 out of 5 with 98% satisfaction rate
  • +5 more outcomes

Companies that use Circle Cardiovascular Imaging

Customer profile

Named customers12 records

Segments4 records

Ideal customer profiles2 records

Circle Cardiovascular Imaging technology and API

Technology

Technology focussed Yes

API detail

Has API
No
API docs
API detail

Core technology

AI maturity

App detail

Integration7 records

AI capability5 records

Feature8 records

Circle Cardiovascular Imaging partnerships and signals

Strategic signal

Partnerships

Four partnerships are on record, tiered core and strategic.

  • Astute ImagingcoreStrategic or Co-development Partner · 18 March 2026Strategic collaboration integrating Astute Imaging's AI-driven vascular analysis technology (aorta, carotid, peripheral arteries) into cvi42 platform. Enables comprehensive cardiovascular workflows including cardiac, vascular, and structural heart analysis in unified platform.
  • AidocstrategicStrategic or Co-development Partner · 18 December 2025Strategic partnership integrating Circle's automated ASPECTS capabilities into Aidoc's aiOS enterprise operating system for neurosciences AI. Enhances Aidoc's stroke diagnosis portfolio with Circle's MR perfusion and automated ASPECTS tools.
  • GE HealthcarecoreTechnology or Integrationcvi42 integrated into GE AW workstation and AW Server. Native integration enables seamless cardiac imaging workflow for GE customers. StrokeSENS also integrated into GE FastStroke software package.
  • Siemens HealthineerscoreTechnology or Integrationcvi42 available on Siemens Healthineers syngo.via workstation. Seamless integration enables cardiac imaging analysis within existing Siemens clinical workflow. StrokeSENS also available on Siemens platforms.

Scale indicators10 records

Recent moves7 records

Expansion highlights6 records

Circle Cardiovascular Imaging competitors and assessment

Company assessment

Broad incumbents

  • GE HealthCare: GE HealthCare's AW Workstation and AW Server bundle Circle's cvi42 alongside GE's own AI imaging portfolio (including FastStroke). GE is both a critical OEM distribution channel and a potential competitor as it expands proprietary AI capabilities.
  • Siemens Healthineers: Siemens Healthineers' syngo.via is both an OEM distribution partner for Circle (cvi42 is integrated into syngo.via) and a direct competitor offering its own AI-powered cardiovascular and CT post-processing tools within the same enterprise accounts.
  • Philips: Philips offers IntelliSpace Portal and a dedicated Cardiovascular Workspace for advanced MR/CT post-processing. It is a broad incumbent imaging vendor that competes head-to-head with cvi42 in hospital cardiology and radiology departments globally.

Direct peers

  • RapidAI: RapidAI offers AI-powered stroke and vascular imaging analysis, directly competing with StrokeSENS in LVO detection, ASPECTS scoring, and CT/MR perfusion quantification across hospital systems.
  • HeartFlow: HeartFlow provides AI-driven coronary CT analysis (FFR-CT) for coronary artery disease assessment. It directly competes with cvi42 | Plaque in the CCTA post-processing market and targets the same cardiology departments.
  • Cleerly: Cleerly is an AI-native direct competitor to cvi42 | Plaque, focused exclusively on coronary plaque quantification and CAD risk stratification from CCTA. Both companies target the same CPT 75577 reimbursement-driven US opportunity.
  • Medis Medical Imaging: Medis is a closely comparable niche cardiovascular imaging software vendor offering post-processing for cardiac MR, CT, and IVUS. It competes with Circle in academic medical centers and tertiary cardiac centers, particularly in Europe.
  • Viz.ai: Viz.ai is the leading AI stroke detection and workflow platform, directly competing with Circle's StrokeSENS module for LVO detection and ASPECTS scoring in hospital neurology and stroke programs.
  • Aidoc: Aidoc is both a Circle partner (Circle's stroke AI is integrated into Aidoc's aiOS) and a broader AI imaging competitor across neurology, cardiology, and radiology workflows. Its enterprise AI operating system overlaps with Circle's hospital penetration strategy.
  • Elucid Bioimaging: Elucid provides AI-based cardiovascular imaging analysis with a focus on plaque characterization and histology-validated quantification. It competes with cvi42 | Plaque in the coronary CT analysis category.

Market position

Strengths5 records

Weaknesses5 records

Competitive moat6 records

Key risks6 records

Key highlights7 records

Customer concentration

Circle Cardiovascular Imaging social profiles

Digital presence

Circle Cardiovascular Imaging compliance and trust

Trust signal

Compliance5 records

Circle Cardiovascular Imaging financial estimates

Financial estimate

Revenue estimate

Valuation estimate

Circle Cardiovascular Imaging leadership team

Management profile

Number of profiles

Profiles7 records

Circle Cardiovascular Imaging subsidiaries and ownership

Company hierarchy

Subsidiaries3 records

Circle Cardiovascular Imaging funding detail

Funding detail

Funding overview

Funding rounds5 records

Investors9 records

Funding detail is available on the Subscription and Enterprise plan.Contact sales →

Circle Cardiovascular Imaging M&A and investment

M&A and investment

M&A1 record

Investments

M&A and investment is available on the Subscription and Enterprise plan.Contact sales →

Frequently asked questions about Circle Cardiovascular Imaging

What does Circle Cardiovascular Imaging do?

Circle Cardiovascular Imaging develops and markets cvi42, a vendor-agnostic AI-powered post-processing platform for cardiovascular and neurovascular imaging. The software provides automated quantification and analysis of cardiac MR, cardiac CT, vascular CT, structural heart interventional planning, electrophysiology, and acute stroke imaging, deployed at hospital systems and academic medical centers. It sells primarily through annual subscriptions, usage-based pricing for plaque analysis, and OEM integrations with GE Healthcare and Siemens Healthineers.

Is Circle Cardiovascular Imaging a public or private company?

Circle Cardiovascular Imaging is a private company. It is classified as private equity controlled and is currently operating.

When was Circle Cardiovascular Imaging founded?

Circle Cardiovascular Imaging was founded in 2007. It employs 101 to 250 people.

Where is Circle Cardiovascular Imaging based?

Circle Cardiovascular Imaging is headquartered in Calgary, Canada, in the North America region.

How does Circle Cardiovascular Imaging make money?

Three revenue lines are on record. Software Licenses (Subscription) is the primary driver. The others are per-Use/Transaction Revenue and professional Services.

Who are Circle Cardiovascular Imaging's main competitors?

Broad incumbents on record are GE HealthCare, Siemens Healthineers and Philips. Direct peers are RapidAI, HeartFlow, Cleerly, Medis Medical Imaging, Viz.ai, Aidoc and Elucid Bioimaging.

Does Circle Cardiovascular Imaging have an API?

No public API is recorded for Circle Cardiovascular Imaging.

What industry is Circle Cardiovascular Imaging in?

Circle Cardiovascular Imaging's product category is Cardiovascular Imaging Software. Its primary akta.pro industry code is HLAGAAAJ, Imaging & Cardiac Safety Core Labs (ECOG/EEG/ECG), with a secondary code of HLACAOAL, Decentralized/Hybrid Trial Enablement (DCT) Platforms. Its NAICS code is 513210 and its SIC code is 3841.

Unlock the full company data

50 free credits on sign-up, no credit card required.

Contact sales
Live signals
AdvfnCircle Cardiovascular Imaging Ready to Help Heart Teams Meet the Next Era of TAVR as CMS Finalizes Expanded Medicare CoverageCMS finalized expanded Medicare coverage for TAVR, including asymptomatic severe aortic stenosis, and Circle Cardiovascular Imaging promoted its cvi42 platform. The policy follows the EARLY TAVR trial, which showed early intervention reduced death, stroke, or heart failure hospitalization to 15.2% versus 24.2%. Circle will host a webinar on September 23, 2026, to support programs.Financial PostCircle Cardiovascular Imaging Ready to Help Heart Teams Meet the Next Era of TAVR as CMS Finalizes Expanded Medicare CoverageCMS finalized expanded Medicare coverage for TAVR, including asymptomatic severe aortic stenosis, and Circle Cardiovascular Imaging announced its cvi42 platform to support the growth. The policy follows the EARLY TAVR trial, which showed early intervention reduced adverse events to 15.2% versus 24.2%. Circle will host a webinar on September 23 to guide programs through the transition.FinancialContent Business PageCircle Cardiovascular Imaging Ready to Help Heart Teams Meet the Next Era of TAVR as CMS Finalizes Expanded Medicare CoverageCMS finalized Medicare coverage for asymptomatic severe aortic stenosis, expanding TAVR access. The policy removes CED requirements for symptomatic patients and requires heart-team review with a surgeon and cardiologist. Circle CVI's cvi42 platform supports the expanded imaging workflow.GlobeNewswireCircle CVI Advances Cardiovascular Imaging Innovation with cvi42 v6.5Circle Cardiovascular Imaging released cvi42 v6.5, adding workflow automation, reporting enhancements, and platform improvements. The update includes automated phase offset correction, editable plaque segmentation, and a Plaque Education Report for referring physicians. The version is available globally to existing customers under current agreements.FinancialContent Business PageCircle CVI Advances Cardiovascular Imaging Innovation with cvi42 v6.5Circle Cardiovascular Imaging Inc. announced the release of cvi42 v6.5, the latest version of its cardiovascular imaging software platform, featuring workflow automation and reporting enhancements across its 4D Flow, CORE CT, and Quantitative Perfusion modules. Key updates include automated phase offset correction and segmentation in the 4D Flow module, editable plaque segmentation in CORE CT, and a new Plaque Education Report designed to improve communication between clinicians and referring physicians. The platform is available globally to existing customers as part of their current agreement, with feature availability varying by regulatory clearance in each market.GlobeNewswireCircle CVI Advances Cardiovascular Imaging Innovation with cvi42 v6.5Circle Cardiovascular Imaging Inc. announced the release of cvi42 version 6.5, an update to its cardiovascular imaging platform, which introduces workflow automation and new reporting features. The new version aims to improve efficiency in clinical workflows and provide clearer communication tools for physicians.FinanceFeedsOpen USD stablecoin: inside the 140-company bid to unseat USDCOpen Standard unveiled Open USD (OUSD) on June 30, 2026, with 140+ members including Visa, Mastercard, and Stripe. The stablecoin is not live, expected to launch on Solana later in 2026, and its yield-sharing model caused Circle's stock to fall 16% to $63.85. Key details like the issuing entity remain undisclosed.Cardiovascular BusinessHow to implement AI-powered coronary plaque analysis software—and ensure you get paidCardiovascular Business and Circle Cardiovascular Imaging are co-hosting a free webinar on implementing AI-powered coronary CT angiography assessments for plaque analysis in patients with suspected coronary artery disease. The webinar will cover implementation workflows, integration, billing, and coding, with presentations from cardiac imaging specialists Kevin Steel, DO, and Audrey Sheely, RN. The timing follows new Medicare coverage and Category 1 CPT codes for AI-powered coronary plaque analysis established in 2024.GlobeNewswireCircle Cardiovascular Imaging Expands cvi42 Platform with Advanced Vascular CT CapabilitiesCircle Cardiovascular Imaging expanded its cvi42 platform to include advanced Vascular CT analysis via Astute Imaging's AI-driven technology. The integration enables unified cardiovascular workflows for cardiac, vascular, and structural heart analysis, improving collaboration across cardiology, radiology, and vascular surgery teams.GlobeNewswireExpanded Insurance Coverage Validates Circle’s AI Approach to Coronary Plaque EvaluationCircle Cardiovascular Imaging Inc. announced that major commercial payers, including Aetna, UnitedHealthcare, Cigna, and Humana, are now covering AI-enabled coronary plaque analysis under permanent Category I CPT code 75577, effective January 1, 2026, replacing prior Category III codes. The expanded insurance coverage extends access to tens of millions of commercially insured patients and is expected to accelerate adoption of CCTA-based plaque assessment. Circle's FDA-cleared cvi42|Plaque solution, which runs on-premise within healthcare institutions, is positioned to benefit from this aligned reimbursement and clinical evidence environment.