Laboratory for Biomechanics, OTH Regensburg
The Laboratory for Biomechanics (LBM) is a university research lab at OTH Regensburg in Bavaria that combines musculoskeletal simulation with motion, force, and biosignal measurement to develop AI-enabled rehabilitation, fall-prevention, osteoporosis, and pelvic-floor applications, funded by BMBF and INTERREG grants.
- Company typePrivate
- Founded-
- HeadquartersRegensburg, Germany
- Headcount1–10
- GTM typeB2B
- OfferingServices
What Laboratory for Biomechanics, OTH Regensburg does
The Laboratory for Biomechanics (Labor für Biomechanik, LBM) is an academic research facility within the Faculty of Mechanical Engineering at Ostbayerische Technische Hochschule Regensburg (OTH Regensburg), a public university of applied sciences in Bavaria, Germany. The lab conducts biomechanics research combining musculoskeletal simulation with experimental motion analysis, supporting clinical applications in orthopedic rehabilitation, fall risk detection, osteoporosis prevention, and pelvic floor disorder prevention. Its technical stack integrates marker-based motion capture (Vicon), IMU-based systems (Xsens Awinda, Link, Dot), markerless capture (Captury), force measurement (Kistler plates, Contrex dynamometer, HBM sensors), biosignal acquisition (Delsys EMG, BioPac MP160), and material testing (Instron E3000, microscopes, µCT), all feeding into validated virtual human body models and AI-based data analysis pipelines.
The lab operates exclusively on a non-commercial, grant-funded model with revenue derived from competitive public-sector research programs — principally BMBF (for the MyReha-digital knee replacement aftercare project) and INTERREG Bavaria–Czechia 2021–2027 (for the 3PD pelvic floor disorder prevention project), supplemented by institutional support from BayWiss and OTH Regensburg. It does not sell products or services commercially; technology transfer occurs through scientific publications on the OTH Regensburg publication server, student theses (Bachelor, Master, research-Master), and collaborative research with healthcare partners. Outputs include a deployable Android test-version osteoporosis prevention app (PreventOsteo), AI-based fall risk algorithms, and sensor-based rehabilitation system prototypes.
The lab is led by Prof. Dr.-Ing. Sebastian Dendorfer and staffed by 7 additional researchers (Dr. Franz Süß, Dr. Igor Lazarev, Ina Adler M.Sc., Mareike Barthel M.Sc., Nikolas Förstl M.Sc., Lukas Gschoßmann M.Sc., Leonhard Stein M.Sc.). It serves as a translational research node rather than a commercial entity, with end beneficiaries including orthopedic rehabilitation patients, elderly fall-risk populations, osteoporosis and pelvic floor disorder cohorts, and university students pursuing biomechanics theses, while its direct counterparties are public funding bodies.
Laboratory for Biomechanics, OTH Regensburg firmographics
Firmographics- Name
- Laboratory for Biomechanics, OTH Regensburg
- Legal name
- Ostbayerische Technische Hochschule Regensburg
- Website
- https://lbm.rcbe.de
- Company type
- Private
- Operating status
- Operating
- Headcount range
- 1–10 employees
- Short description
- The Laboratory for Biomechanics (LBM) is a university research lab at OTH Regensburg in Bavaria that combines musculoskeletal simulation with motion, force, and biosignal measurement to develop AI-enabled rehabilitation, fall-prevention, osteoporosis, and pelvic-floor applications, funded by BMBF and INTERREG grants.
- Ownership category
- akta.pro rank
Laboratory for Biomechanics, OTH Regensburg industry classification
Industry- Product category
- Academic Biomechanics Research
- NAICS
- Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology) (541715), Research and Development in the Physical, Engineering, and Life Sciences (54171)
- SIC
- Services-Commercial Physical & Biological Research (8731), Laboratory Analytical Instruments (3826)
- akta.pro primary industry
- Metrology, Calibration & Testing Equipment (Balances, pH/DO, Standards) (HLAGAIAL)
- akta.pro secondary industry
- Clinical Trial Analytics, Risk-Based Monitoring (RBM) & Quality Management (HLACAOAI)
Keywords
Where Laboratory for Biomechanics, OTH Regensburg is headquartered
LocationHeadquarters
- HQ city
- Regensburg
- HQ country
- Germany
- HQ region
- Europe
Offices1 record
Markets served
Laboratory for Biomechanics, OTH Regensburg business model
Business model- GTM type
- B2B
- Offering type
- Services
- Cost components
- Personnel, Technology or R&D, Operations
Revenue model
- Research Funding: Funded by government research grants including BMBF (Bundesministerium für Bildung und Forschung) for MyReha-digital project and INTERREG Bavaria – Czechia 2021–2027 for 3PD project on pelvic floor disorder prevention. Revenue is derived from competitive research grants rather than commercial product sales.
Go-to-market motion1 record
Marketing channels1 record
Laboratory for Biomechanics, OTH Regensburg product offering
Product offeringCore offering
The Laboratory for Biomechanics (LBM) is a university research department within the Faculty of Mechanical Engineering at OTH Regensburg that conducts biomechanics research combining musculoskeletal simulation, marker-based and markerless motion capture, force measurement, EMG/biosignal acquisition, and AI-based data analysis. It develops and validates virtual human models, runs funded projects such as MyReha-digital (BMBF-funded knee replacement aftercare), PreventOsteo (wearables-based osteoporosis prevention including an Android test app), 3PD (INTERREG-funded pelvic floor disorder prevention), and AI-based fall risk detection, while also supervising Bachelor, Master, and Research Master theses.
Product overview
The Laboratory for Biomechanics (LBM) at OTH Regensburg is a university research facility that provides biomechanics research capabilities rather than commercial products. The portfolio consists of core research services in musculoskeletal simulation, motion analysis, and rehabilitation technology development, supported by specialized laboratory equipment for motion measurement (Vicon, Xsens, Captury), force measurement (Kistler, Contrex), biosignal acquisition (BioPac, Delsys EMG), and material testing (Instron). Research projects including MyReha-digital (sensor-based knee replacement rehabilitation), PreventOsteo (wearable-based osteoporosis prevention with Android app), 3PD (pelvic floor disorder prevention), and AI-based fall risk analysis represent the primary outputs of the laboratory's research activities.
Differentiator
Problem solved
Functional benefit
Brands
- MyReha-digital: A sensor-based rehabilitation system for post-operative care following knee replacement surgery, funded by BMBF.
- PreventOsteo
- 3PD (Pelvic Floor Disorder Prevention)
Products and services
- Musculoskeletal Simulation Research Development, validation and application of virtual human models for calculating loads and stresses in the human body during various activities. Used in research collaborations with healthcare partners.
- Motion Analysis Research Quantification of muscle activities, forces and movements using marker-based (Vicon Motion Capture), IMU-based (Xsens Awinda, Link, Dot), markerless (Captury), and various open-source camera systems. Supports movement studies for healthcare and academic collaborations.
- Osteoporosis Prevention App (PreventOsteo) Android application developed as part of the PreventOsteo project for osteoporosis prevention using wearable devices. Currently distributed as a test version for research purposes.
- MyReha-digital Rehabilitation System Sensor-based rehabilitation system for aftercare following knee joint replacement, funded by BMBF (German Federal Ministry of Education and Research) as part of the MyReha-digital project.
Quantifiable outcome
- Development of sensor-based rehabilitation system for post-knee replacement aftercare (MyReha-digital)
- +2 more outcomes
Companies that use Laboratory for Biomechanics, OTH Regensburg
Customer profileSegments2 records
Ideal customer profiles2 records
Laboratory for Biomechanics, OTH Regensburg technology and API
TechnologyTechnology focussed No
API detail
- Has API
- No
- API docs
- API detail
Core technology
AI maturity
App detail
AI capability5 records
Feature7 records
Laboratory for Biomechanics, OTH Regensburg partnerships and signals
Strategic signalScale indicators2 records
Recent moves5 records
Expansion highlights5 records
Laboratory for Biomechanics, OTH Regensburg competitors and assessment
Company assessmentBroad incumbents
- Noraxon USA: Commercial provider of EMG, motion capture, and biomechanics measurement systems used widely in clinical and research settings. Comparable as an ecosystem participant that supplies the type of instruments (EMG, IMU) the lab uses, and competes in applied biomechanics research enablement.
- Vicon Motion Systems (Oxford Metrics): Industry-standard marker-based motion capture system used in clinical gait analysis, biomechanics research, and rehabilitation labs globally. Lab uses Vicon as a primary instrument; comparable as the commercial standard for the type of measurement capability the lab provides as research services.
- Kistler Group: Manufacturer of high-precision force plates and biomechanical measurement instruments used in gait analysis, sports biomechanics, and rehabilitation research. Lab uses Kistler force plates; comparable as commercial infrastructure for the type of biomechanics measurement the lab performs.
- Movella (Xsens): Provider of IMU-based motion capture systems (Xsens Awinda, Link, Dot) used in biomechanics, sports science, and rehabilitation research. Lab uses Xsens as a primary instrument; comparable commercial enablement of the same biomechanics research workflows.
Others
- Delsys Inc. Manufacturer of EMG sensors and bioelectric signal acquisition systems widely used in biomechanics research labs. Lab uses Delsys EMG as primary muscle activity measurement tool; comparable as the commercial supplier underpinning the lab's biosignal analysis capabilities.
Direct peers
- Institute of Applied Mechanics, FAU Erlangen-Nürnberg: Chair of Applied Mechanics at Friedrich-Alexander-Universität conducts musculoskeletal simulation, biomechanics modeling, and movement analysis research. Closely comparable German academic lab with similar virtual human model development and rehabilitation focus.
- Julius Wolff Institute, Charité Berlin: Charité's biomechanics research institute conducting musculoskeletal research, motion analysis, and rehabilitation engineering. Directly comparable as an academic biomechanics lab using similar motion capture, force measurement, and simulation methods, but with significantly larger scale and clinical integration.
- TU Munich - Professorship of Biomechanics: Technical University of Munich's biomechanics group conducts musculoskeletal simulation, orthopedic biomechanics, and motion analysis. Regional German peer with substantially larger team and industry partnership pipeline.
- Institute for Biomechanics, ETH Zurich: ETH Zurich's Institute for Biomechanics performs musculoskeletal research, motion analysis, and orthopedic biomechanics. Premier European biomechanics research lab with similar measurement and simulation stack but much greater scale and funding base.
- Heidelberg University - Institute of Sport and Sport Science: Academic biomechanics and movement science research group at Heidelberg University. Comparable German academic peer performing motion analysis, EMG, and rehabilitation research with similar instrumentation and methods.
Market position
Strengths4 records
Weaknesses4 records
Competitive moat3 records
Key risks6 records
Key highlights6 records
Customer concentration
Laboratory for Biomechanics, OTH Regensburg social profiles
Digital presenceLaboratory for Biomechanics, OTH Regensburg financial estimates
Financial estimateRevenue estimate
Valuation estimate
Laboratory for Biomechanics, OTH Regensburg leadership team
Management profileNumber of profiles
Profiles8 records
Laboratory for Biomechanics, OTH Regensburg funding detail
Funding detailFunding overview
Funding rounds
Investors
Funding detail is available on the Subscription and Enterprise plan.Contact sales →
Laboratory for Biomechanics, OTH Regensburg M&A and investment
M&A and investmentM&A
Investments
M&A and investment is available on the Subscription and Enterprise plan.Contact sales →
Frequently asked questions about Laboratory for Biomechanics, OTH Regensburg
What does Laboratory for Biomechanics, OTH Regensburg do?
The Laboratory for Biomechanics (LBM) is a university research department within the Faculty of Mechanical Engineering at OTH Regensburg that conducts biomechanics research combining musculoskeletal simulation, marker-based and markerless motion capture, force measurement, EMG/biosignal acquisition, and AI-based data analysis. It develops and validates virtual human models, runs funded projects such as MyReha-digital (BMBF-funded knee replacement aftercare), PreventOsteo (wearables-based osteoporosis prevention including an Android test app), 3PD (INTERREG-funded pelvic floor disorder prevention), and AI-based fall risk detection, while also supervising Bachelor, Master, and Research Master theses.
Is Laboratory for Biomechanics, OTH Regensburg a public or private company?
Laboratory for Biomechanics, OTH Regensburg is a private company. It is classified as state government owned and is currently operating.
When was Laboratory for Biomechanics, OTH Regensburg founded?
Laboratory for Biomechanics, OTH Regensburg was founded in -1. It employs 1 to 10 people.
Where is Laboratory for Biomechanics, OTH Regensburg based?
Laboratory for Biomechanics, OTH Regensburg is headquartered in Regensburg, Germany, in the Europe region.
How does Laboratory for Biomechanics, OTH Regensburg make money?
One revenue line is on record: research Funding.
Who are Laboratory for Biomechanics, OTH Regensburg's main competitors?
Broad incumbents on record are Noraxon USA, Vicon Motion Systems (Oxford Metrics), Kistler Group and Movella (Xsens). Delsys Inc. is listed as an others. Direct peers are Institute of Applied Mechanics, FAU Erlangen-Nürnberg, Julius Wolff Institute, Charité Berlin, TU Munich - Professorship of Biomechanics, Institute for Biomechanics, ETH Zurich and Heidelberg University - Institute of Sport and Sport Science.
Does Laboratory for Biomechanics, OTH Regensburg have an API?
No public API is recorded for Laboratory for Biomechanics, OTH Regensburg.
What industry is Laboratory for Biomechanics, OTH Regensburg in?
Laboratory for Biomechanics, OTH Regensburg's product category is Academic Biomechanics Research. Its primary akta.pro industry code is HLAGAIAL, Metrology, Calibration & Testing Equipment (Balances, pH/DO, Standards), with a secondary code of HLACAOAI, Clinical Trial Analytics, Risk-Based Monitoring (RBM) & Quality Management. Its NAICS code is 541715 and its SIC code is 8731.